Aerodynamic Line Pin

In Stock

Porcelain aerodynamic line pin insulators in 11, 22 and 33 kV options with Pattern C threads. Select DULALP-11-275, DULALP-22-450 or DULALP-33-920 to match the required creepage and pin reference.

Choose the exact SKU to order or request a quote. For fitting or supply help, call (08) 9258 8444 or email sales@engsup.com.au.

P/N: ALP Category:

Description

Porcelain aerodynamic line pin insulators

These aerodynamic line pin insulators are porcelain fittings in 11, 22 and 33 kV options. Each uses a Pattern C pin thread. Select the full DULALP SKU to match the voltage, creepage distances and mounting pin listed for your assembly.

First, check the required part number against the table below. The three options differ in body size and creepage. They also have different pin references, so voltage alone is not enough to confirm a replacement.

ALP voltage, creepage and pin references

Order SKUVoltageCreepage X–YCreepage X–ZListed pinMinimum failing load
DULALP-11-27511 kV235 mm275 mmC/150/77 kN
DULALP-22-45022 kV365 mm450 mmC/200/1111 kN
DULALP-33-92033 kV755 mm920 mmC/300/711 kN

The corresponding catalogue numbers are ALP/11/275, ALP/22/450 and ALP/33/920. The X–Y and X–Z values follow two different creepage paths in the drawing on page 10-5 of the Dulmison catalogue. Neither value is the overall height.

Check the body dimensions

Catalogue partAHeight DEF
ALP/11/275136 mm152 mm76 mm136 mm
ALP/22/450148 mm200 mm74 mm160 mm
ALP/33/920240 mm320 mm133 mm240 mm

All three have a listed B dimension of 102 mm and C dimension of 76 mm. Use the catalogue drawing to locate each letter and check the required clearances. Also, confirm the pin and mounting hardware needed for the installation; the pin reference does not establish what is supplied with the insulator.

The photograph illustrates the general porcelain form. However, it does not show each voltage option to scale. For a physical fit check, use the dimensions for the selected SKU.

Select and order your insulator

  • Match the voltage and creepage paths to the assembly specification.
  • Check the specified pin and conductor attachment arrangement.
  • Confirm the mechanical requirement before placing an order.

The minimum failing load is a failure rating, not a working-load limit.

For another insulator style, view our TE longrod insulators. To order this range, select the required DULALP row and quantity, then add it to your cart or quote request.

For part matching or supply help, call (08) 9258 8444 or email sales@engsup.com.au with the exact SKU and drawing.

Additional information

Voltage