TE Longrod Insulators

In Stock

Grey TE composite longrod insulators with silicone housing and CT couplings. Choose from three SKUs with listed 70 or 120 kN strain ratings and 1157 or 2120 mm nominal creepage.

Confirm the nominal system voltage for LR-CS120CT425-2120CSG before ordering; 425 kV is its impulse withstand rating. Select the exact SKU to order or request a quote. Call (08) 9258 8444 or email sales@engsup.com.au for help.

P/N: LRCS Category:
ThumbnailVariation TitleP/NPriceQuantityAdd To Cart
TE Longrod Insulators
Nominal systems voltage kv: 35
Lightning impulse withstand voltage kv: 235
Kn: 70 (Strain)
LR-CS070CT235-1157CSG $98.46
TE Longrod Insulators
Nominal systems voltage kv: 35
Lightning impulse withstand voltage kv: 235
Kn: 120 (Strain)
LR-CS120CT235-1157CSG $90.46
TE Longrod Insulators
Lightning impulse withstand voltage kv: 425
Kn: 120 (Strain)
LR-CS120CT425-2120CSG $123.08

Description

TE longrod insulators with silicone housing

These TE longrod insulators have a composite body, grey silicone housing and CT couplings. Three variants are available, with listed strain ratings of 70 or 120 kN. Choose the full part number to match the required mechanical rating, voltage characteristics and creepage distance.

First, check the complete SKU against your specification. The two 235 kV impulse withstand options have the same listed nominal system voltage and creepage distance. However, their strain ratings differ. The 425 kV impulse withstand option has a longer nominal creepage distance of 2120 mm.

Compare the available longrod options

Part number / SKUListed strain ratingNominal system voltageLightning impulse withstandNominal creepage
LR-CS070CT235-1157CSG70 kN35 kV235 kV1157 mm
LR-CS120CT235-1157CSG120 kN35 kV235 kV1157 mm
LR-CS120CT425-2120CSG120 kNConfirm for your application425 kV2120 mm

The electrical figures, housing material and coupling code are listed on page 138 of the Engineering Supplies catalogue. The strain ratings are shown against the individual product options. All three use the CT coupling designation.

Check voltage and fitting requirements

Lightning impulse withstand voltage is different from nominal system voltage. The catalogue does not give a nominal system voltage for LR-CS120CT425-2120CSG. Therefore, confirm that requirement before selecting this variant.

Also, keep creepage distance separate from overall length and dry arcing distance. To check physical fit, use a drawing for the exact part number. The shared photograph illustrates the range; it does not establish the length or shed count of each option.

  • Match the specified strain rating to the selected SKU.
  • Check the system voltage, impulse withstand and creepage requirements.
  • Confirm the CT end fittings and mating hardware from the assembly drawing.
  • Check the required length, clearances and quantity before ordering.

For other insulator styles, you can view our guy strain insulators. Use the requirements of your assembly to select the appropriate type.

Order TE longrod insulators

Select the row with the required SKU, then choose your quantity and add it to the cart or quote request. For help with drawings or supply, call (08) 9258 8444 or email sales@engsup.com.au.

Additional information

Nominal Systems Voltage kV

35

Lightning Impulse Withstand Voltage kV

235, 425

kN

70 (Strain), 120 (Strain)